PIGTAIL TYPE
Model: SY(Q)
(stopcock or valve) mounted underneath.
APPLICATIONS
Siphons are used mainly to protect pressure instruments, gauges, switches and transmitters directly coming in contact with high temperature process fluids or vapours. These are mounted between process and pressure instrument. they reduce process pulsation and generate cooling effect to save the instrument.
Features:
- Designs per DIN 16282 or to industrial standards
- Permissible temperatures to 400° C
- Nominal pressures to 160 bar
TECHNICAL DESCRIPTION:
- Material used : SS304/SS316,A105, Monel, Inconel,
- Allowable Pressure : 6000PSI
- Max Temperature : 120° C
- Size : 1/4”, 3/8”, 1/2"
- Thread Type : Male-Female, Female-Female, Male- Male, BSP/NPT Thread.